ps-bg-blue
SAFE
RELIABLE
AFFORDABLE
GENTLE

Aquarius 300B

Effective reliable sterilization.

Simply effective. Aquarius 300B, a class B autoclave with an 18-litre nickel plated copper chamber, ensures safe sterilization in an extremely practical and intuitive way and fits easily into any studio, thanks to its compact design. The autoclave is able to sterilize a wide range of different instruments, even the most delicate ones, such as hollow instruments and porous loads: its controlled heating system eliminates the risk of thermal shock as well as ensuring greater energy efficiency.

Safety and speed: thanks to its special rapid cycle, instruments are sterilized in less than 20 minutes, combining the utmost care for patients with improved performance in the studio. In full compliance with the EN13060 standard, Aquarius ensures data traceability for each sterilization cycle through a direct PC connection or with the optional built-in printer.

BACTERIOLOGICAL FILTER

During the drying phase, the filter provides bacteriologically pure air (with a 99.97% filtration factor).

PORTA TRIPLE SAFETY DOOR

The door is fitted with a triple safety lock to prevent unintentional opening while the autoclave is operating.

INTUITIVE INTERFACE

Information can be easily recorded and monitored through the PC connection.

CLEAN WATER/DIRTY WATER

Effective management of clean and waste water, thanks to the practical taps.

    Technical Data
    OVERALL DIMENSIONS447 x 438 x 625 mm (L x H x P)
    CHAMBER DIMENSIONSØ 240 – 384 mm (P)
    CHAMBER SIZE17,5 L
    WEIGHT (empty)45 Kg
    POWER SUPPLY VOLTAGE230 V 50/60 Hz
    POWER CONSUMPTION900 W – 1920 W
    OPERATING TEMPERATURE+10 -+ 40° C
    ALTITUDEbetween 0 and 2000 metres above sea level
    OPERATING RANGEIndoor use
    Relative humidity 85%
    Maximum line-voltage deviation ±10%
    Installation category II
    Pollution level 2
    USABLE SPACE180 x 282 x 160 mm LxPxH
    WATER CONSUMPTION VOLUME0,6 litres
    TANK CAPACITY (clean water and used water)4 litres each
    AUTO SWITCH-OFFAfter 30’ of stand by at the end of cycle
    Sterilization Cycle
    CycleTemperatureSterilizationDrying phaseVacuumCycle typeMax load
    B134134° C5′10′3B4 kg solid – 1,5 kg porous
    B121121° C20′11′3B4 kg solid – 1,5 kg porous
    S134134° C3′5′2S4 kg solid
    CUSTOM105-135° C3′5′-14′2-3-44 kg solid – 1,5 kg porous
    HELIX TEST134° C3’30”10′3TEST
    B&D TEST134° C3’30”10′3TEST
    VACUUM TEST<35° C3

    Request information

      Press ctrl or cmd to select multiple options.

      Press ctrl or cmd to select multiple options.



      Your message was successfully sent!

      Thanks for contacting us, we will reply to you as soon as possible!